| Aspect |
Impacts |
Significance Evaluation |
Legal & Other Requirements |
Operational Controls & Measuring
Protocols |
| Emulsifiers |
Natural Resource Use: none
Air Impacts: none
Water Impacts: oily residue
Land Impacts: none
Other Impacts: none
|
Qualitative Analysis: none
Quantitative Analysis: magnitude/severity=1
frequency=5
Significant?
Qualitative: yes
Quantitative: no |
RCRA: solid waste, USTs
CERCLA: none
EPCRA: wastewater discharge
CWA: stormwater (if exposed)
CAA: none
Spill reporting
|
Operational Controls: material and container specification, collection and disposal procedure
Parametric Measures: none
Performance Measures: amount used per unit of production |
| Alkalines |
Natural Resource Use: none
Air Impacts: none
Water Impacts: regulated toxic
Land Impacts: corrosive waste
Other Impacts: none |
Qualitative Analysis: threat to environment/ personnel
Quantitative Analysis: magnitude/severity=2
frequency=5
Significant?
Qualitative: yes
Quantitative: yes |
RCRA: hazardous waste
CERCLA: spills
EPCRA: Sections 301-303, 604, 311-312, 313
CWA: wastewater discharge, stormwater (if exposed)
CAA: NSR if “new source,” if “non-attainment,” HAPs, operating permits if “major source,” enhanced monitoring if “signficant emissions”
Spill reporting |
Operational Controls: material specification, delivery/ dispensing procedure, bath temperature/ exhaust control system
Parametric Measures: none
Performance Measures: amount used per unit of production |
| Solvents |
Natural Resource Use: none
Air Impacts: HAP, VOC-precursor, odor
Water Impacts: potential spill
Land Impacts: listed waste
Other Impacts: none
|
Qualitative Analysis: threat to environment/ personnel
Quantitative Analysis: magnitude/severity=2
frequency=5
Significant?
Qualitative: yes
Quantitative: yes |
RCRA: hazardous waste, USTs
CERCLA: spills
EPCRA: Sections 301-303, 604, 311-312, 313
CWA: wastewater discharge, stormwater (if exposed)
CAA: NSR if “new source,” CTG, if “non-attainment,” HAPs, MACT, operating permits if “major source,” enhanced monitoring if “signficant emissions”
Spill reporting |
Operational Controls: material specification, delivery/ dispensing procedure, bath temperature/ exhaust control system
Parametric Measures: none
Performance Measures: amount used per unit of production |