| Aspect |
Impacts |
Significance Evaluation |
Legal & Other Requirements |
Operational Controls & Measuring
Protocols |
| Electricity |
Natural Resource Use: nonrenewable
Air Impacts: SOx/NOx/CO, CO2, VOC/CO/NOx, PM, Visual
Water Impacts: none
Land Impacts: none
Other Impacts: none
|
Qualitative Analysis: resource use, threat to environment/ personnel
Quantitative Analysis: magnitude/severity=1
frequency=5
Significant?
Qualitative: yes
Quantitative: no |
RCRA: none
CERCLA: none
EPCRA: none
CWA: none
|
Operational Controls: type of maintenance of saws
Parametric Measures: none
Performance Measures: amount used per unit of production |
| Scrap Wood |
Natural Resource Use: renewable
Air Impacts: none
Water Impacts: none
Land Impacts: solid waste, reuse boiler
Other Impacts: none
|
Qualitative Analysis: reusable resource
Quantitative Analysis: magnitude/severity=1
frequency=5
Significant?
Qualitative: yes
Quantitative: no |
RCRA: solid waste
CERCLA: none
EPCRA: none
CWA: none
|
Operational Controls: operation procedure, operator training
Parametric Measures: none
Performance Measures: percentage of scrap |
| Wood Fines |
Natural Resource Use: none
Air Impacts: respirable PM
Water Impacts: none
Land Impacts: solid waste, reused boiler
Other Impacts: none
|
Qualitative Analysis: reusable resource, threat to environment/ personnel
Quantitative Analysis: magnitude/severity=2
frequency=5
Significant?
Qualitative: yes
Quantitative: yes |
RCRA: none
CERCLA: none
EPCRA: none
CWA: none
CAA: NSR, if "new source"; Non-Attainment, if
"non-attainment"; Operating Permits, if "major source"; Enhanced Monitoring, if "large operation" |
Operational Controls: none
Parametric Measures: control device operating setpoints, flow rates/pressure drop
Performance Measures: capacity efficiency |
| Urea
- Formaldehyde |
Natural Resource Use: none
Air Impacts: formaldehyde, VOC
Water Impacts: potential spill
Land Impacts: none
Other Impacts: none
|
Qualitative Analysis: threat to environment/ personnel
Quantitative Analysis: magnitude/severity=2
frequency=4
Significant?
Qualitative: yes
Quantitative: yes |
RCRA: Hazardous Waste
CERCLA: spill potential, reportable if release
EPCRA: notify LEPC if presence greater (301-303), notify if accidental release of quantity (304), depends on storage quantity (311-312), 313 if reporting criteria met
CWA: none
|
Operational Controls: resin specification
Parametric Measures: none
Performance Measures: amount used per unit of production |
| Solvent |
Natural Resource Use: none
Air Impacts: solvent, VOC
Water Impacts: potential spill
Land Impacts: none
Other Impacts: none
|
Qualitative Analysis: threat to environment/ personnel
Quantitative Analysis: magnitude/severity=2
frequency=4
Significant?
Qualitative: yes
Quantitative: yes |
RCRA: hazardous waste
CERCLA: none
EPCRA: none
CWA: none
|
Operational Controls: none
Parametric Measures: none
Performance Measures: amount used per unit of production |
| Noise |
Natural Resource Use: none
Air Impacts: none
Water Impacts: none
Land Impacts: none
Other Impacts: noise
|
Qualitative Analysis: threat to environment/ personnel
Quantitative Analysis: magnitude/severity=1
frequency=5
Significant?
Qualitative: yes
Quantitative: no |
RCRA: none
CERCLA: none
EPCRA: none
CWA: none
|
Operational Controls: building design
Parametric Measures: complaints
Performance Measures: testing, decibel recordings |